Fluid Ports:
MAO-500: 1/2" FNPT
Mounting:
MAO-500: Mount with Inlet vertical (Inlet port down),
Outlet horizontal
Temperature Operating Range:
AMBIENT: 32° to 220° F (0° to 104° C)
MEDIA: 32° to 220° F (0° to 104° C)
Performance:
REPEATABILITY: ± 3% full scale
LINEARITY: ± 4% full scale
TOTAL ACCURACY: ± 10%
Installation: (For detailed information
see Installation and Maintenance Sheet.) Control valves should
be placed downstream of the MAO flow meter. The flow meter should
never be installed so that it drains completely when flow ceases.
A 10 micron filter is recommended.
Electrical Specifications:
Power Requirements:
VOLTAGE 12-18 VDC Regulated, ±10%
CURRENT 20 mA maximum
Output:
ANALOG (PART No.-10) 0-5 VDC, 2 mA maximum load
-or-
DIGITAL (Part No.-20) Square Wave, 6.5 V peak to peak 200 Hz full
scale or specify other.
TTL Available - consult factory
Load Impedance: 2,500W to infinity
Leads: PVC Jacketed, 22 AWG 96", strain
relief
Notes: Calibration is performed using common
ground.
Calibration with isolated power supply is available; please specify
when ordering.
How to Order
MAO
Model |
500
Size |
T
Body Material |
10
Electrical Output |
C
Cover Bolts |
AA
Flow Range |
|
|
| T |
Teflon® |
| B |
Brass |
| S |
Stainless Steel |
|
| 10 |
Standard Analog Output |
| 20 |
Standard Digital Output |
|
| C |
Standard Cover Bolts |
| B |
Long Bolts for Mounting |
|
(See Chart)
AA
BB
ZZ * Special Calibration |
|