| Operation
When flow is increased, the magnetic piston is forced against
a bias spring. As the magnet comes near the adjustable
read switch it actuates, indicating proper flow. When
flow decreases the spring forces the piston in the opposite
direction deactuating the reed switch an indicating
a reduced or no flow situation.
-
All models field adjustable
-
Deactuation (decreasing flow)
averages 40% less than actuation (increasing
flow).
-
Repeatability ±2%
-
Correction must be made for attitudes
other than horizontal.
-
Unit will pass greater flows.
Corrections must be made for other gases,
line pressure and temperatures. Please consult your
representative or the factory. |