Best
for applications where the normal flow to
set point is 10:1 or less |

Wet Stations
Shipboard Water Systems
CVD Furnaces Cooling Water
Biomedical Instruments
Vacuum Systems
Coolant Failure Alarm |
Features |
-
Low
Minimum Operating Pressure
-
Close
ON-OFF differential
-
Ease
of adjustability
-
In
Line 180 Degree Porting
-
Monitors
Gases or Liquids
-
Materials:
316ss, Brass, Teflon
|
-
Confirms:
Normal flow conditions
-
Senses:
High Flow or Low Flow Conditions
-
Water
or Explosion Proof Covers
-
Output:
Switch Contact
|
| Operation
With no flow
present, the magnetic piston rests on the bottom of
the bypass bore. When flow is established the piston
is forced upward by the bypass flow and actuates the
reed switch. The bypass flow is controlled by manual
adjustment of the flow control vane. When flow decreases
the piston moves downward and the reed switch deactuates.
-
Actuation
points for air at 68*F and 14.7 PSIA with increasing
flow.
-
Deactuation
(decreasing flow) averages 10% less than actuation
(increasing flow).
-
Repeatability
± 2%.
-
Unit
will pass greater flows.
Corrections
must be made for other gases, line pressure and temperatures.
Please consult your representative or
the factory. |
Calibration
Range
| MODEL |
AIR
SLPM (SCFM) |
WATER
LPM (GPM) |
| |
MINIMUM |
MAXIMUM |
MINIMUM |
MAXIMUM |
| 500BP |
6 (0.20) |
991
(35) |
0.11
(0.03) |
15.14
(4) |
| 500BPHF |
23
(0.80) |
2124
(75) |
0.38
(0.10) |
37.85
(10) |
|
Pressure
Loss Table
AIR
FLOW RATE
SLPM (SCFM) |
WATER
FLOW RATE
LPM (GPM) |
DP TO
ATMOSPHERE
MBARS
(PSID) |
| 84.9
(3) |
3.8
(1) |
17.2
(0.25) |
| 566.3
(20) |
15.1
(4) |
51.7
(0.75) |
| 1557.4
(55) |
30.3
(8) |
233.0
(3.38) |
| 1925.5
(68) |
37.9
(10) |
362.0
(5.25) |
| 2265.3
(80) |
64.4
(17) |
517.1
(7.50) |
| At
any given flow rate, pressure differential remains
the same regardless of the actuation point. |
|